Pacemaker (nodal) cells vs ventricular myocytes
he key idea is that the heart needs two things to happen reliably, every beat:
A timing system that decides when each beat should occur and in what order chambers activate – the pacemaker cells.
A power system that turns that electrical signal into a strong, coordinated pump – the ventricular myocytes.
Those are fundamentally different problems, so the cells specialised for each look and behave differently.
For now, we’re focussing on the pacemaker (or nodal) cells.
The role of nodal tissue (SA + AV node)
Nodal tissue is responsible for timing and initiating the electrical impulses of the heartbeat (automatic rhythm generation)
SA node sets the basic rate because it can initiate impulses spontaneously.
This creates a regular rhythm without needing external nerve input.
The autonomic nervous system then adjusts that “default pace” up or down.
In most excitable cells (including working atrial and ventricular myocytes), there is a stable resting membrane potential (RMP). This is the baseline electrical “starting point” between action potentials, where the cell sits at a relatively constant voltage until it is stimulated. Functionally, that suits working myocardium: these cells should remain electrically quiet and only fire when instructed, so contraction stays coordinated.
Pacemaker cells are different because their job is to initiate the heartbeat, not just respond to it. To generate a regular rhythm without external triggering, they cannot remain at a fixed RMP. Instead, after each beat they repolarise to their most negative voltage (often called the maximum diastolic potential) and then spontaneously depolarise back toward threshold. That gradual drift is what creates automatic rhythm generation.
We describe the pacemaker action potential in phases because the membrane voltage changes in a repeatable sequence each cycle. The phases are simply labels that help you track what the cell is doing at each stage:
moving steadily toward firing,
firing an action potential,
then resetting so the process can start again.
This cyclic behaviour is what allows nodal cells to act as a reliable timekeeper: the rate depends largely on how quickly the membrane drifts up to threshold each cycle, and the autonomic nervous system can speed this up or slow it down to adjust heart rate.
With that in mind, the pacemaker cycle can be summarised as:
Phase 4: spontaneous depolarisation toward threshold
Phase 0: the action potential upstroke (the “firing” event)
Phase 3: repolarisation back to the most negative level (reset)
Pacemaker cells achieve this using a different “electrical toolkit” from working myocardium: they rely mainly on If (HCN channels) and Ca²⁺ currents, rather than the fast Na⁺ currents that dominate ventricular myocyte depolarisation.

The pacemaker action potential: phases 4 → 0 → 3
Phase 4: pacemaker potential (spontaneous depolarisation)
Starting point ≈ –60 mV – the cell is “relaxed” after its last beat.
Funny current (If) switches on.
Hyperpolarisation-activated cyclic nucleotide-gated (HCN) channels open allowing Na⁺ and K⁺ to move along their concentration gradients
These HCN channels act like a tiny trickle-charger letting more Na⁺ seep in than K⁺ leaks out.
Membrane voltage creeps upward – due to the extra positive charge from Na⁺
Around –50 mV a few T-type Ca²⁺ channels join in, giving an extra push.
When the voltage hits –40 mV (threshold) we progress to Phase 0
The speed of this slope sets the heart rate – steeper slope, faster rate.
Phase 0 – Rapid Depolarisation
At the threshold of about −40 mV
L-type Ca²⁺ channels open causing a Ca²⁺ influx.
This produces a slow upstroke, reaching roughly: +10 to +20 mV
Because Ca²⁺ channels open more sluggishly than Na⁺ channels in working myocytes, the up-stroke is rounded rather than vertical
High-yield link: because Phase 0 is calcium-dependent in nodal tissue, anything that reduces L-type Ca²⁺ current slows nodal depolarisation and (in AV node) slows conduction.
Phase 3: repolarisation
Repolarisation occurs when:
L-type Ca²⁺ channels close, stopping the inward surge.
Voltage-gated K⁺ channels open → K⁺ exits, pulling the voltage back down.
- Once it returns to–60 mV, the funny current re-engages and the whole cycle starts again.
Autonomic modulation of the pacemaker action potential (SA/AV node)
Autonomic input changes heart rate mainly by altering Phase 4 (the pacemaker potential): how quickly the membrane depolarises from the maximum diastolic potential to threshold.
Sympathetic nervous system: positive chronotropy (HR ↑)
Trigger: Noradrenaline and adrenaline bind β₁-adrenoceptors
Signal pathway: β₁ → Gₛ activation → ↑ adenylate cyclase activity → ↑ intracellular cAMP
Effect on Phase 4:
cAMP directly increases HCN channel activity → ↑ If
This steepens the Phase 4 slope (faster spontaneous depolarisation)
Result: Threshold is reached sooner → more frequent action potentials → heart rate increases

Parasympathetic nervous system: negative chronotropy (HR ↓)
At rest, the heart is typically under dominant vagal tone, keeping the heart rate below the intrinsic SA node rate (~ 90–120 bpm).
Trigger: Vagus nerve releases acetylcholine (ACh) which binds M₂ receptors
Signal pathway: M₂ → Gᵢ activation → inhibits adenylate cyclase → ↓ cAMP
Effects on Phase 4 (two key actions):
Hyperpolarisation: the Gβγ subunit directly opens K ACh channels → ↑ K⁺ efflux
→ maximum diastolic potential becomes more negative (further from threshold)Reduced If: ↓ cAMP → ↓ HCN activity → flatter Phase 4 slope
Result: It takes longer to reach threshold → fewer action potentials per minute → heart rate decreases