What is Work?
In physics, work is done when a force moves something through a distance.
So the essential idea is:
No movement, no work.
You can push very hard against a wall, but if the wall does not move, you are using energy and generating tension, but you are not doing external mechanical work on the wall.
A simple equation is:
Work (J) = Force × Distance
This tells us that work depends on two things:
how much force is applied
how far the object moves
How does this apply to the heart?
The ventricle is a muscular pump. Its job is to generate force and use that force to move blood.
So in the heart, work means:
the mechanical energy the ventricle uses to move blood by generating pressure and ejecting volume
Because blood is a fluid, cardiac work is usually expressed as:
Work = Pressure × Volume change
This is the fluid equivalent of force times distance.
Why pressure rather than force?
In a fluid system, pressure reflects the force being applied over an area
The relevant “movement” is the change in volume as blood is ejected
So when the ventricle contracts and ejects blood into the aorta, it is doing mechanical work on that blood.
External and Internal Work
When the ventricle contracts, it uses chemical energy from ATP and converts it into mechanical energy. Not all of that mechanical energy becomes useful to actually pump blood forward.
That total mechanical energy can be thought of as:
External work = useful work done ejecting blood
Internal work = energy generated within the myocardium that does not appear as forward stroke work (work done for everything except pumping blood)
Think of pushing a heavy box across the floor.
The distance the box actually moves is like external work: useful output.
The effort you spend straining, generating tension, and producing heat in your muscles is like internal work.
So if you push very hard but the box barely moves:
external work is low
internal energy expenditure is high
That is similar to a failing ventricle or a ventricle pumping against very high afterload.
On the pressure–volume diagram, these are represented by different areas.

External Work
Definition
External work is the mechanical work the ventricle performs to eject blood into the aorta against pressure.
This is the useful hydraulic work of the heart.
Mathematically, for a pressure–volume system:
Work = Pressure × change in volume
On the graph
This is the area inside the pressure–volume loop.
This is because the loop traces the full cycle of filling, contraction, ejection, and relaxation, and the enclosed area represents the net work transferred from the ventricle to the blood during one beat.
So:
Bigger loop area → greater external stroke work
Smaller loop area → less external stroke work
In practical terms
External work is what actually moves blood forward into the circulation.
It depends mainly on:
Stroke volume
Ejection pressure
So if the ventricle ejects a large volume at high pressure, external work is high.
Internal work
Definition
Internal work is the energy developed by the myocardium during contraction that does not become external hydraulic work.
It is mechanical energy generated within the ventricle, much of which is ultimately dissipated as:
heat
wall tension
internal fibre shortening without useful ejection
You can think of it as the “cost of generating force” rather than the “useful output”.
On the graph
This is not the area inside the loop.
It is the area to the left of the loop, between the loop and the ESPVR, down toward the volume axis.
This is often referred to as potential energy.
So on a PV diagram:
External work = area inside the loop
Internal work / potential energy = area between the end-systolic point, the ESPVR line, and the diastolic portion/volume axis
Why it exists
At the end of systole, the ventricle still contains energy stored in the myocardium as tension and elastic deformation.
Not all generated force has been converted into blood movement.
That leftover energy is released during relaxation and largely lost as heat.
In Summary
External work
Useful mechanical work done ejecting blood
Equals the area inside the pressure–volume loop
Also called stroke work
Internal work
Energy generated by the myocardium that does not produce forward blood flow
Represented by the area to the left of the loop under the ESPVR
Often called potential energy
Total mechanical energy
Pressure–volume area = external work + internal work
Closely related to myocardial oxygen consumption
Linking cardiac work to oxygen demand
The myocardium extracts a very large proportion of oxygen from coronary blood at rest — around 70%. That means, unlike many other tissues, it has little reserve for extra oxygen extraction. When myocardial work increases, the heart cannot simply “take more oxygen out” of the blood; it usually has to meet demand by increasing coronary blood flow.
This is why increases in cardiac work matter so much clinically:
more work → more myocardial oxygen consumption
if coronary flow cannot rise appropriately → supply–demand mismatch
if mismatch is significant → myocardial ischaemia
So when we talk about internal and external work, we are not just describing graph geometry. We are really describing how hard the myocardium is working and therefore how much oxygen it needs.
The main determinants of myocardial work and oxygen consumption
Heart rate
Each beat requires:
electrical activation
calcium handling
tension development
contraction and relaxation
So if heart rate rises, the heart performs more tension-generating cycles per minute.
This increases oxygen demand in a fairly direct way.
Contractility
A stronger contraction requires:
greater calcium flux
more cross-bridge cycling
more ATP use
So increasing inotropy increases myocardial oxygen demand, even if haemodynamics appear improved.
This is an important nuance: an inotrope may improve cardiac output, but it often does so at the cost of higher oxygen consumption.
Ventricular wall tension
This is one of the most important concepts linking PV loops to clinical physiology.
Wall tension is described by Laplace’s law:
T = ( P × r ) / 2 h
where:
T = wall tension
P = intraventricular pressure
r = ventricular radius
h = wall thickness
This means wall tension rises when:
pressure rises
ventricular radius rises
wall thickness falls
Why does this matter?
Because wall tension is a major determinant of myocardial oxygen demand. The harder the myocardium has to generate tension, the more oxygen it consumes.
Pressure work versus volume work
Pressure work
This refers mainly to work required to overcome high afterload, such as:
systemic hypertension
aortic stenosis
vasoconstriction
This is energetically expensive because the ventricle must generate high pressure, which markedly increases wall tension and therefore internal work.
So pressure work tends to consume a lot of oxygen.
Volume work
This refers more to work associated with ejecting a larger volume, usually due to higher preload.
Increasing preload increases ventricular radius, which also increases wall tension, so it does increase oxygen demand. However, in general, volume work increases external work more than internal work.
That makes it metabolically less costly than severe pressure work.
This is why, clinically, hypertension is often more dangerous for myocardial oxygen balance than a moderate increase in preload.
Why pressure work is especially “expensive”
When afterload is high, the ventricle must spend more energy developing pressure before and during ejection. Much of this extra cost appears as internal work / tension development, rather than efficient forward flow.
So on the pressure–volume loop:
a high-afterload ventricle may have a tall, narrow loop
stroke volume may fall
but oxygen demand may still be high
This is a classic situation of poor energetic efficiency.
In other words, the heart may be spending a lot, but getting relatively little useful output in return.
RV vs LV
The right ventricle normally pumps into a low-resistance pulmonary circulation, so its external work is much lower than that of the left ventricle — roughly 20–25% of LV external work.
That is why the RV is normally a thin-walled chamber.
However, this also means it is poorly designed to cope with sudden increases in afterload.
So if pulmonary vascular resistance rises abruptly — for example with:
pulmonary embolism
severe hypoxia
hypercapnia
high airway pressures
acute pulmonary hypertension
the RV can fail quite quickly.
Clinically, this is the RV version of pressure work becoming suddenly very expensive.