Every beat, the heart moves a volume of blood out of the left ventricle. That volume is the stroke volume — what was in the ventricle at the end of filling, minus what is left after the squeeze. Heart rate sets how often this happens. Stroke volume is how much blood is pumped for each beat.
Three things decide the amount.
The first is how full the ventricle is when the squeeze begins. Cardiac muscle has a useful property: stretch a fibre before it contracts and it contracts harder. So a fuller ventricle ejects more. That filling is preload.
The second is the load the ventricle has to work against to get blood out. Before any blood moves, pressure inside the ventricle has to climb high enough to force the aortic valve open, and it then has to keep pushing against whatever the arteries are doing. Tight vessels, stiff arteries or a narrowed valve all make that harder, and less blood leaves per beat. That load is afterload.
The third is the strength of the squeeze itself — how hard the muscle contracts for a given filling and a given load. This is set inside the muscle cell, and it comes down to how much calcium reaches the contractile machinery. That is contractility.
So: fill it more and stroke volume rises. Make it push against more resistance and stroke volume falls. Make the muscle pump with more force and stroke volume rises.
In a living heart the three never move one at a time. Stretching the fibres improves the squeeze. Raising the load also improves the squeeze. Speeding the heart up improves the squeeze but cuts the filling time. Under anaesthesia we tend to move all three at once, and often in the same unhelpful direction.
Defining the three determinants
Each of the three has a laboratory definition — what it actually is in a strip of muscle — and a clinical approximation, which is what we can measure at the bedside.
Cardiac output is the product of how often the heart beats and how much it moves each time:
CO = HR × SV
where:
CO (L/min) = cardiac output
HR (beats/min) = heart rate
SV (ml) = stroke volume
SV = EDV − ESV
where:
SV (ml) = stroke volume
EDV (ml) = end-diastolic volume, the volume in the ventricle at the end of filling
ESV (ml) = end-systolic volume, the volume left behind at the end of the squeeze
Typical adult values: an EDV of about 120 ml and a stroke volume of about 70 ml, leaving roughly 50 ml behind.
The fraction of the ventricle’s contents that leaves per beat is the ejection fraction:
EF (%) = (EDV − ESV) / EDV × 100
where:
EF (%) = ejection fraction
EDV (ml) = end-diastolic volume
ESV (ml) = end-systolic volume
With the numbers above that comes to about 58%. An ejection fraction below 45% is taken as evidence of impaired systolic pump function.
Preload
- Laboratory definition: the length of the cardiac muscle fibre — strictly, the sarcomere length — just before contraction begins.
- Clinical approximation: end-diastolic volume, measured on echocardiography.
- Weaker approximation: end-diastolic pressure, measured through a central venous catheter or pulmonary artery catheter. CVP (central venous pressure) approximates right ventricular end-diastolic pressure; PCWP (pulmonary capillary wedge pressure) approximates left ventricular end-diastolic pressure, written LVEDP.
Why pressure is the weaker surrogate: what we want is fibre length, and fibre length tracks volume. Pressure only tracks volume if the ventricle’s stiffness is normal. A stiff ventricle — ischaemic, hypertrophied — sits at a high filling pressure with a small filling volume, so a reassuring CVP can sit on top of a poorly filled ventricle.
Afterload
- Definition: the sum of the forces, both elastic and kinetic, opposing ventricular ejection.
- Physical equivalent: ventricular wall stress during ejection.
- Clinical approximation: systemic vascular resistance (SVR), or mean arterial pressure.
That definition avoids the words “resistance” and “impedance” on purpose. Both have strict meanings in physics and get used loosely in medicine, and arterial resistance is only one part of what the ventricle is working against.
Contractility
- Definition: everything other than heart rate, preload and afterload that changes how well the myocardium performs. Also called inotropy.
- Physical basis: how much calcium reaches the contractile proteins, and how readily those proteins respond to it.
- Clinical approximation: every available index is contaminated by preload or afterload to some degree, so there is no clean metric for contractility only.
Preload: how full the ventricle is
Preload is the first of the three: how far the ventricle has been filled, and therefore stretched, by the time the squeeze begins. What sets it is everything upstream of the ventricle — how much blood is coming back, and how readily the chamber accepts it.
Stretch a cardiac muscle fibre before it contracts and it generates more force. Push the stretch too far and force falls away again.
Why? Force comes from cross-bridges — myosin heads binding actin and pulling. How many can form depends on how the two sets of filaments are lined up.
- At short sarcomere lengths the thin filaments from opposite ends of the sarcomere overlap each other and get in the way, and the sarcomere distorts → fewer useful cross-bridges → less force.
- Stretch towards about 2.2 µm and the filaments line up for the greatest number of cross-bridges → maximum force.
- Stretch beyond that and the filaments are pulled apart → fewer cross-bridges → less force. This does not happen in a normal heart, but it does in ventricular failure.
- Stretch also makes the myofilaments more sensitive to calcium, so the same calcium signal produces more force.
In a normal heart that optimal sarcomere length of about 2.2 µm corresponds to an LVEDP of roughly 10–12 mmHg. This length–tension behaviour is the Frank–Starling relationship.
Plot stroke volume against filling and you get the ventricular function curve — steep at normal filling pressures, flattening as the ventricle approaches its optimum. A heart working on the steep part gains a lot of stroke volume from a little extra filling, which is exactly what a fluid challenge is testing.
What sets preload
Preload is whatever filling the ventricle ends up with, so it is decided by two separate things: how fast blood arrives, and how easily the chamber takes it.
How fast blood arrives: venous return
At steady state, what comes back equals what goes out. The driving pressure for venous return is the difference between the pressure filling the venous system and the pressure in the right atrium:
VR = (MSFP − RAP) / RVR
where:
VR (L/min) = venous return
MSFP (mmHg) = mean systemic filling pressure
RAP (mmHg) = right atrial pressure
RVR = resistance to venous return
Mean systemic filling pressure is the pressure everywhere in the circulation if the heart stopped and the pressures equalised. It is an index of how full the system is relative to how stretchy it is, and it is normally about 7 mmHg. The veins hold roughly 65% of the circulating volume, which is why venous tone dominates this number.
Raising mean systemic filling pressure increases venous return:
- More volume — transfusion or fluid resuscitation.
- Less venous compliance — venoconstriction, whether from sympathetic outflow or from an α₁ agonist. Squeezing a stretchy reservoir raises the pressure inside it.
Lowering it reduces venous return:
- Haemorrhage, or any other loss of circulating volume.
- More venous compliance — venodilatation from neuraxial block, anaesthetic agents or vasodilators.
Raising right atrial pressure reduces venous return, because it cuts the pressure gradient:
- Positive pressure ventilation, and PEEP (positive end-expiratory pressure) in particular.
- Cardiac tamponade or a constricted pericardium — the right heart cannot fill without pressure rising.
- Right ventricular failure.
Lowering it increases venous return. Spontaneous inspiration does exactly this: negative intrathoracic pressure pulls right atrial pressure down and draws blood into the chest, the “respiratory pump”.
Raising resistance to venous return reduces it:
- Standing up, which pools blood in the legs.
- Compression of the great veins — the gravid uterus, obesity, and the pneumoperitoneum of laparoscopy.
Working against all of this is the skeletal muscle pump: leg muscles contracting against competent venous valves push blood back towards the heart.
How easily the chamber takes it
- Ventricular compliance — how much the chamber fills for a given filling pressure. Reduced if the chamber is stiff (or non-compliant) by things like ischaemia, hypertrophy and diastolic dysfunction generally, so the same filling pressure produces a smaller volume.
- Wall thickness — a thick-walled ventricle has a smaller cavity, so increased wall thickness reduces preload. Hypertrophy and hypertrophic obstructive cardiomyopathy (HOCM).
- Pericardial compliance — constriction and tamponade limit how far the chamber can expand at all.
- Atrial kick — atrial contraction tops the ventricle up at the end of diastole and makes a significant contribution to filling. Lose it in atrial fibrillation and preload falls.
- Filling time — diastole is what shortens as heart rate rises, so tachycardia cuts filling.
- Valve disease — atrioventricular valve disease obstructs filling and reduces preload; semilunar valve incompetence lets blood back into the ventricle and raises it.
At induction: most anaesthetic agents venodilate, so mean systemic filling pressure falls. Start positive pressure ventilation and right atrial pressure rises. Preload is attacked from both ends of the gradient at once, which is why a hypovolaemic patient can drop their blood pressure so dramatically at this moment.
Laparoscopy: the pneumoperitoneum compresses the inferior vena cava, raising resistance to venous return and cutting preload. Head-up positioning for upper abdominal work pools blood in the legs on top of that.
Afterload: the load against ejection
Afterload is the second lever, and it works in the opposite direction to the first: the more the ventricle has to push against, the less it ejects per beat. It is everything standing between the ventricular cavity and blood actually moving down the aorta.
The ventricle creates cavity pressure by generating tension in its wall, and it is that wall tension which opens the valve and drives ejection. So the real load on the muscle is the tension each fibre has to produce — the wall stress.
Think of a balloon. A big floppy balloon needs far more tension in its skin to hold a given pressure than a small thick-walled one does. Same pressure, very different demand on the material.
σ ∝ (P × r) / T
where:
σ = ventricular wall stress
P (mmHg) = ventricular transmural pressure
r (cm) = ventricular chamber radius
T (cm) = ventricular wall thickness
This is the ventricle’s version of Laplace’s law. Three things follow straight from it:
- Higher pressure in the cavity → more wall stress → more afterload.
- A bigger chamber → more wall stress for the same pressure. A dilated ventricle is working harder than its blood pressure suggests.
- A thicker wall → less wall stress, because the same total tension is shared between more sarcomeres. This is what concentric hypertrophy achieves in chronic pressure overload.
Wall stress also sets myocardial oxygen consumption, so anything that raises afterload raises myocardial oxygen demand with it.
What sets afterload
Transmural pressure: the cavity against the chest
Transmural pressure is the difference between the pressure inside the ventricle and the pressure outside it in the chest.
- Negative intrathoracic pressure raises transmural pressure and therefore afterload, because the ventricle has to generate a bigger pressure change to eject into an aorta that lies largely outside the chest.
- Positive intrathoracic pressure does the reverse: PEEP reduces left ventricular afterload.
In acute pulmonary oedema: the patient is working hard to breathe and generating large negative intrathoracic pressures. That raises left ventricular afterload, which worsens left ventricular failure, which worsens the oedema, which increases the work of breathing again. Applying CPAP reverses the sign of the intrathoracic pressure and breaks the loop, which is part of why it works so quickly.
Outflow obstruction
- Aortic stenosis — a fixed narrowing, so the ventricle must reach a far higher pressure to push the same volume through.
- HOCM — dynamic obstruction from the hypertrophied septum, worse when the ventricle is underfilled or contracting vigorously.
Systemic arterial impedance
Once the valve is open, the arterial tree sets the load. It has three components: resistance, inertia and compliance.
Resistance sits mostly in the arterioles, and what governs it is given by the Hagen–Poiseuille relationship:
R = 8ηl / πr⁴
where:
R = resistance to flow
η = viscosity of blood
l = length of the vessel
r = radius of the vessel
- Radius is raised to the fourth power, so it dominates everything else. It is set by how constricted the resistance vessels are, which is the lever every vasoconstrictor and vasodilator pulls.
- Vessel length is essentially fixed.
- Viscosity moves mainly with haematocrit, so it rises in polycythaemia.
Clinically this is captured as systemic vascular resistance:
SVR = ((MAP − CVP) × 80) / CO
where:
SVR (dyn·s/cm⁵) = systemic vascular resistance
MAP (mmHg) = mean arterial pressure
CVP (mmHg) = central venous pressure
CO (L/min) = cardiac output
Inertia is the mass of the column of blood that has to be accelerated with each beat, and it matters more at higher heart rates.
Compliance is how much the big arteries give as blood is ejected into them:
- During ejection the aorta and great arteries distend, absorbing part of the stroke volume and blunting the peak systolic pressure. In diastole they recoil, maintaining pressure and flow — the Windkessel effect.
- A stiff aorta cannot do this, so pressure rises further for the same ejected volume and afterload rises.
- A stiff aorta also carries reflected pressure waves back from the periphery faster. Arriving in diastole they augment coronary filling; arriving during systole, as they do in a stiff arterial tree, they add to afterload instead.
Chamber radius and wall thickness
These come straight back out of the wall stress equation. A larger end-diastolic volume means a larger chamber radius and therefore more wall stress, so filling the ventricle raises its own load. A thicker wall shares the tension between more sarcomeres and reduces it.
Raising the blood pressure with a vasoconstrictor: phenylephrine and metaraminol act mainly at α₁ receptors on vascular smooth muscle and raise systemic vascular resistance. The pressure reading improves, but afterload has risen and cardiac output often falls — partly from the extra load, partly from the reflex bradycardia that follows the rise in pressure. In a patient whose problem is a poor pump rather than a vasodilated circulation, that is a bad trade.
Contractility: the strength of the squeeze
Contractility is the third lever, and the only one that lives inside the muscle cell. Hold the filling constant and hold the load constant, and whatever is left that changes the force of contraction is contractility.
Force comes from cross-bridges cycling, and cross-bridges only cycle when calcium is present. So the sequence from electrical signal to force runs:
- Depolarisation spreads along the sarcolemma and down the T-tubules → voltage-gated L-type calcium channels open → a small amount of calcium enters the cell.
- That calcium opens ryanodine receptors (RyR2) on the sarcoplasmic reticulum → a much larger release of stored calcium. This is calcium-induced calcium release.
- Calcium binds troponin C → tropomyosin is displaced off the myosin binding sites on actin → cross-bridges form and cycle → force.
- Calcium is pumped back into the sarcoplasmic reticulum by the SR calcium ATPase and extruded from the cell → tropomyosin re-covers the binding sites → relaxation.
Electrical signal → Ca²⁺ entry → Ca²⁺ release from SR → cross-bridges cycle → force → Ca²⁺ removed → relaxation
So: anything that raises peak calcium at the myofilaments, or makes the myofilaments more sensitive to it, raises contractility. Anything that reduces either lowers it.
What raises contractility
- Sympathetic stimulation. Noradrenaline at cardiac β₁ receptors → Gₛ protein → adenylate cyclase activated → cyclic AMP rises → phosphorylation of the L-type calcium channels and of phospholamban (the brake on the SR calcium pump) → more calcium enters and the store refills faster → a stronger and faster contraction, and faster relaxation.
- Circulating catecholamines — adrenaline released from the adrenal medulla, acting at the same receptors.
- Parasympathetic blockade, which removes vagal restraint.
- Inotropic drugs — the sympathomimetics and the phosphodiesterase inhibitors.
- A faster heart rate — the Bowditch (Treppe) effect. At faster rates there is less time between beats to clear calcium from the cytosol, so it accumulates and each contraction is stronger. This operates over roughly 40–140 beats/min.
- A higher afterload — the Anrep effect. An abrupt rise in afterload is followed within a few beats by a rise in contractility, which partly defends stroke volume against the extra load.
What lowers contractility
- Myocardial ischaemia and hypoxia. Less ATP is produced → the sarcoplasmic reticulum cannot handle calcium properly → weaker contraction. Anaerobic metabolism then produces intracellular acidosis, which makes it worse.
- Acidosis from any other cause, by the same route.
- Volatile anaesthetic agents — all of them are negative inotropes.
- β-blockers and calcium channel blockers.
- Heart failure. Peak calcium is lower and sarcoplasmic reticulum uptake of calcium is reduced. The practical consequence is loss of contractile reserve: the failing heart gains far less from sympathetic stimulation than a normal one does.
Measuring contractility
No index is clean, because contractility is defined as what is left over once preload and afterload are accounted for, and every measurable signal carries some of both.
- dP/dt max — the maximum rate of rise of ventricular pressure, taken during isovolumetric contraction. A steeper rise means a more forceful contraction. It is afterload-independent, because the aortic valve has not yet opened, but it is preload-dependent, and measuring it needs a catheter in the ventricle.
- End-systolic pressure–volume relationship (ESPVR) — the line drawn through the end-systolic points on a pressure–volume plot. The steeper its slope, the greater the contractility. It is the least load-dependent index available, but it needs several loops recorded under different loading conditions.
- Ejection fraction — the one used most, because any echo gives it. It falls when contractility falls, but it also falls when afterload rises and rises when preload rises, so it is not a pure measure of the muscle.
Seeing all three on a pressure–volume loop
Plotting ventricular pressure against ventricular volume through a single beat puts all three determinants on one picture, because each one moves the loop in its own direction.

Going anticlockwise from the moment filling finishes:
- At end-diastole the ventricle holds around 120 ml, and the mitral valve shuts.
- Isovolumetric contraction: pressure climbs with no change in volume, so the trace is vertical.
- At around 80 mmHg — aortic diastolic pressure — the aortic valve opens.
- Ejection: volume falls while pressure continues up towards about 120 mmHg, then tails off.
- The aortic valve shuts, and isovolumetric relaxation gives another vertical line, pressure falling at constant volume.
- The mitral valve opens and filling begins again.
The width of the loop is the stroke volume. The area inside it is the external work the ventricle did, because work is pressure multiplied by volume.
Two lines bound the loop. The ESPVR passes through the end-systolic corner, and its slope is contractility. The EDPVR (end-diastolic pressure–volume relationship) runs along the bottom through the filling points, and its shape reflects ventricular compliance.
Why the three never move alone
In a patient the three determinants are coupled: change one and at least one of the others moves with it. These couplings are what make bedside prediction hard.
- Preload changes afterload. A larger end-diastolic volume means a larger chamber radius, and wall stress rises with radius. Filling the ventricle raises its own load.
- Afterload changes contractility. The Anrep effect: raise the load and contractility rises within a few beats, which partly defends stroke volume.
- Heart rate changes both contractility and preload. Faster rates raise contractility through the Bowditch effect, but shorten diastole and so cut filling time. Past roughly 140 beats/min the lost filling wins and cardiac output falls.
- The two ventricles are coupled in series. Whatever the right ventricle ejects becomes the left ventricle’s preload one circulation later, and the Frank–Starling relationship is what keeps the two outputs matched. If the left ventricle persistently ejected even 1 ml less per beat than the right, litres of blood would accumulate in the pulmonary circulation within the hour.
Why CVP misleads: a single reading gives a pressure, not a volume, and tells you nothing about whether this ventricle will respond to filling. Interpreting it needs clinical context. This is why fluid responsiveness is judged by what stroke volume does in response to a challenge, rather than just the filling pressure.
Moving stroke volume in theatre
Each thing we do in theatre acts through one or more of the three determinants, and most of them move more than one.
| Intervention | Preload | Afterload | Contractility | Net effect on stroke volume |
|---|---|---|---|---|
| Fluid bolus | ↑ (raises MSFP) | ↑ slightly (larger radius) | – | ↑ if on the steep part of the curve |
| Head-down tilt or leg raise | ↑ | – | – | ↑ transiently |
| Positive pressure ventilation and PEEP | ↓ (raises RAP) | ↓ for the left ventricle | – | Usually ↓, but can help in left ventricular failure |
| Neuraxial block | ↓ (venodilatation) | ↓ (arteriolar dilatation) | – | ↓ |
| Volatile agents | ↓ (venodilatation) | ↓ | ↓ | ↓ |
| Phenylephrine, metaraminol (α₁) | ↑ slightly | ↑↑ | – | Often ↓ |
| Noradrenaline (α₁ > β) | ↑ (venoconstriction) | ↑↑ | ↑ slightly | Variable |
| Adrenaline (β at low dose, α₁ at high) | ↑ | ↓ low dose, ↑ high dose | ↑↑ | ↑ |
| Dobutamine (β₁ > β₂) | – | ↓ slightly | ↑↑ | ↑ |
| Ephedrine (direct and indirect) | ↑ | ↑ | ↑ | ↑ |
| Milrinone, enoximone (PDE III inhibitors) | ↓ (venodilatation) | ↓ | ↑ | ↑ |
| Laparoscopy | ↓ (IVC compression) | ↑ | – | ↓ |
| β-blockade | – | – | ↓ | ↓ |
The phosphodiesterase III inhibitors reach contractility by a different route. By blocking the breakdown of cyclic AMP they raise contractility without going through the β receptor, which is useful when β receptors are downregulated, and they dilate the vasculature at the same time. Raising contractility while dropping afterload is why they are called inodilators.
The hypotensive patient after induction: the usual picture has all three moving against you at once. Venodilatation has cut preload, the induction agent and volatile have cut contractility, and positive pressure ventilation has raised right atrial pressure. Fluid and a vasoconstrictor both help because they act on different parts of the problem, and which to reach for first depends on which determinant you think has moved most.
In aortic stenosis: afterload is fixed and high, so stroke volume cannot be rescued by reducing the load. The ventricle is hypertrophied and stiff, which makes it unusually dependent on preload and on atrial kick for filling, and unusually intolerant of tachycardia. Keep it full, keep it in sinus rhythm, keep the rate controlled, and protect the coronary perfusion pressure.
In the failing ventricle: the function curve is flat, so extra filling buys very little stroke volume and produces pulmonary oedema instead. Reducing afterload, which a normal heart barely notices, produces a large gain in stroke volume here — which is why vasodilators and inodilators earn their place in heart failure while doing little in a normal heart.
In summary
- Stroke volume is end-diastolic volume minus end-systolic volume, and three things set it: preload, afterload and contractility.
- Preload is fibre length at the start of contraction, approximated clinically by end-diastolic volume. More stretch means more cross-bridges and a stronger contraction, up to an optimum sarcomere length of about 2.2 µm. It is set by venous return — mean systemic filling pressure, right atrial pressure and resistance to venous return — and by how readily the ventricle, pericardium and atria allow the chamber to fill.
- Afterload is the sum of the forces opposing ejection, best understood as ventricular wall stress: pressure × radius ÷ wall thickness. It is set by intrathoracic pressure, outflow obstruction, arterial resistance and compliance, chamber size and wall thickness.
- Contractility is everything else that changes the force of contraction, and it comes down to calcium — how much reaches the myofilaments and how sensitive they are to it. Sympathetic tone and inotropes raise it; ischaemia, acidosis, volatile agents and β-blockade lower it.
- On a pressure–volume loop, preload moves the end-diastolic point, afterload moves the end-systolic point, and contractility swings the ESPVR.
- They are coupled: filling raises afterload, afterload raises contractility through the Anrep effect, and a faster rate raises contractility through the Bowditch effect while cutting filling time.
- Almost everything we do in anaesthesia moves more than one of them at the same time.