Frank–Starling mechanism and heart failure

In this note:

The heart has to pump out exactly what it receives. Blood comes back from the veins at a rate that changes constantly — with posture, breathing, bleeding, exercise — and whatever arrives has to leave again over the next few beats. The two ventricles sit in series, so they also have to match each other almost perfectly. The heart solves this by building the adjustment into the muscle itself.

The rule is simple: the more a ventricle fills during diastole, the harder it contracts, and the more blood it ejects with that beat (the stroke volume). Filling stretches the muscle fibres, and a stretched fibre generates more force. This is the Frank–Starling mechanism, also called Starling’s law of the heart.

Plot filling on the horizontal axis and stroke volume on the vertical, and you get the Frank–Starling curve. It rises steeply at first, then flattens. A normal heart works on the steep part, so a small change in filling produces a large change in output — which is what makes the matching automatic and quick.

There is a limit. Stretch the muscle past its optimum and force starts to fall, because the contractile filaments are drawn too far apart to pull on each other properly. A normal heart never reaches that point. A failing heart does.

Heart failure is the state in which the heart cannot produce enough output for the tissues. On the curve, the failing ventricle sits on a lower, flatter line: the same filling buys less stroke volume, and the maximum it can reach is lower. The body compensates by driving the heart harder and by holding on to salt and water, which pushes the ventricle further along its curve. That works for a while. When it stops working, extra filling produces no extra output and simply raises the pressure behind the ventricle — which is where the breathlessness, the raised jugular venous pressure and the swollen ankles come from.

So two different things can happen to a patient: you can move a heart along the curve it is already on by changing how much it fills, or you can move the whole curve up or down by changing how strongly the muscle contracts.

From filling to force

Filling and force are the two ends of the Frank–Starling mechanism. Filling is described as preload and force shows up as stroke volume, and between them sits the arrangement of contractile proteins that makes stretch matter.

Cardiac output is the volume the heart pumps each minute, and it comes from two things: how much leaves per beat, and how often beats happen.

CO = SV × HR

where:
CO (L/min) = cardiac output
SV (mL) = stroke volume, the volume ejected by one ventricle in one beat
HR (beats/min) = heart rate

Stroke volume is the difference between what is in the ventricle at the end of filling and what is left behind after ejection.

SV = EDV − ESV

where:
SV (mL) = stroke volume
EDV (mL) = end-diastolic volume, the volume in the ventricle just before it contracts
ESV (mL) = end-systolic volume, the volume remaining after ejection

In a resting adult the left ventricular end-diastolic volume is about 120 mL and stroke volume about 70 mL, giving a cardiac output of roughly 5 L/min (at 70bpm).

Preload

Preload is how stretched the muscle fibre is just before it contracts. Strictly that means the sarcomere length at the end of diastole, which can’t be measured in a living patient, so it gets approximated:

  • End-diastolic volume, usually measured on echocardiography. This is the closest practical substitute.
  • End-diastolic pressure, measured through a central venous catheter or a pulmonary artery catheter. Central venous pressure (CVP) approximates right ventricular end-diastolic pressure; pulmonary capillary wedge pressure (PCWP) approximates left ventricular end-diastolic pressure (LVEDP).

Pressure is the poorer substitute, because the pressure a given volume generates depends on how compliant (how easily stretched) the ventricle is, and ventricular compliance is itself changed by disease.

The other two determinants of stroke volume are afterload and contractility: afterload is the load the ventricle has to overcome before and during ejection, and contractility is the intrinsic strength of the muscle at a given preload and afterload.

The length–tension relationship

The sarcomere is the basic contractile unit of muscle: thick filaments of myosin interleaved with thin filaments of actin, bounded at each end by a Z-disc. Force is produced when myosin heads bind actin and pull — each binding is a cross-bridge — so the force a sarcomere can generate depends on how many cross-bridges can form. That depends on how far the filaments overlap, which depends on sarcomere length.

  • Maximum force occurs at a sarcomere length of about 2.2 µm. Here cross-bridge formation is at its highest and the thin filaments from opposite ends do not overlap one another. In a normal heart this corresponds to an LVEDP of roughly 10–12 mmHg.
  • Below 2.2 µm the thin filaments overlap each other and get in the way, so the tension generated falls. Contractile energy is also lost working against friction, and the sarcomere becomes distorted.
  • Above 2.2 µm the filaments are drawn apart, fewer cross-bridges can form, and force falls. This doesn’t happen in a normal heart, but it does in ventricular failure.
  • At about 3.6 µm there is no overlap left and the active tension developed is zero.
Sarcomere length–tension curve: active tension rises to a maximum at 2.2 µm and falls to zero at 3.6 µm, with the overstretched falling limb marked as the failing ventricle
Figure 1 — Force peaks at a sarcomere length of about 2.2 µm. The normal heart works on the rising limb; a dilated, failing ventricle slides onto the falling limb.

Stretch does a second thing as well: it raises the sensitivity of the myofilaments to calcium, so the same rise in intracellular calcium produces more force. Titin, an elastic protein that spans half the sarcomere and behaves like a molecular spring, limits how far the sarcomere can be pulled apart in the first place.

Filling stretches the fibre → better filament overlap and greater calcium sensitivity → more cross-bridges → stronger contraction → larger stroke volume

That is the Frank–Starling mechanism: the strength of ventricular contraction depends on the initial length of the resting fibres. It is intrinsic to the muscle — nerves and hormones play no part in it.

In atrial fibrillation: atrial contraction, the atrial kick, delivers the last part of ventricular filling. Lose it and end-diastolic volume falls, the sarcomeres sit shorter than optimal, and stroke volume drops. A fast ventricular rate compounds the problem, because a short diastole leaves less time to fill.

Reading the Frank–Starling curve

The relationship between filling and output is drawn as a curve: preload on the horizontal axis, stroke volume on the vertical (or cardiac output, if heart rate is held constant). It is also called the ventricular function curve, and its shape explains both how a healthy heart adjusts and what goes wrong when it fails.

The curve is non-linear:

  • It rises steeply at low and normal filling, so small changes in preload produce large changes in stroke volume.
  • It flattens at high filling. Past the plateau, more filling buys very little extra output.
  • A normal heart sits on the steep part with plenty of reserve above it, which is why a healthy patient absorbs a litre of fluid or a moderate bleed without much change in cardiac output.

Moving along the curve, and moving the curve

Two separate things can change:

  • Changing preload moves the heart along the curve it is already on. Giving fluid, tipping the patient head-down, and losing blood all do this.
  • Changing contractility moves the heart onto a different curve. Positive inotropy shifts the whole curve up and to the left, so any given preload yields a greater stroke volume. Negative inotropy shifts it down and to the right.
Frank–Starling curves of stroke volume against preload: a normal curve, a higher curve with increased contractility, and a lower heart failure curve that peaks and then falls at high preload
Figure 2 — Fluid moves the heart along its curve; inotropy moves it onto a different curve. The failing curve is lower, flatter and eventually falls.

Fluid or inotrope: this is the difference between the two. A fluid challenge gains output when the ventricle is on the steep part of its curve, because there is output to be gained. Give fluid to a ventricle already on its plateau and you raise the filling pressure, push fluid out into the lungs, and get almost no extra flow.

At induction: most intravenous induction agents and volatile anaesthetics are negative inotropes and vasodilators at the same time. The curve shifts down while preload falls, so a patient with little reserve can lose a lot of cardiac output in the first few minutes.

In the ischaemic or acidotic heart: contractility depends on how the cell handles calcium, and handling calcium costs energy. Hypoxia cuts production of ATP (the cell’s energy currency), which impairs the sarcoplasmic reticulum — the intracellular store that releases calcium for contraction and takes it back up for relaxation. The intracellular acidosis of anaerobic metabolism makes it worse. The curve drops as a result, which is why correcting hypoxia and acidosis is part of treating a low cardiac output.

How the two sides of the heart stay matched

The right and left ventricles pump in series, so over any length of time they must move identical volumes. The Frank–Starling mechanism is what enforces that, beat by beat, with nothing coordinating it centrally.

  • Venous return to the right ventricle rises.
  • Right ventricular end-diastolic volume rises, so right ventricular stroke volume rises.
  • Pulmonary blood flow rises.
  • Left ventricular filling rises, so left ventricular end-diastolic volume rises.
  • Left ventricular stroke volume rises to match.

The margin for error is tiny. If the left ventricle ejected just 1 mL per beat less than the right, the pulmonary circulation would hold over 3 litres of extra blood within an hour.

In right ventricular failure: the matching runs in the unhelpful direction too. A right ventricle that can’t deliver its stroke volume underfills the left, so left ventricular output falls even though the left ventricle itself is healthy. Filling the patient doesn’t fix it, because the limit is the right ventricle’s ability to move volume forward — and a dilated right ventricle bows the interventricular septum into the left, reducing left ventricular filling further.

Venous return and where the heart settles

The Frank–Starling curve says what the heart will do with a given filling. What that filling actually is depends on the circulation delivering blood back to it, so cardiac output is set by the heart and the vasculature together.

Venous return is the rate at which blood comes back to the heart, and at steady state it equals cardiac output. The veins hold around 65% of the total blood volume, so they are the reservoir the heart draws on.

VR = (MSFP − RAP) / RVR

where:
VR (L/min) = venous return
MSFP (mmHg) = mean systemic filling pressure, the pressure in the circulation if the heart stopped and flow ceased, normally about 7 mmHg
RAP (mmHg) = right atrial pressure
RVR = resistance to venous return

Read it as a pressure gradient driving flow. Blood returns because the pressure in the systemic vessels is higher than the pressure in the right atrium.

  • Raise MSFP — by transfusing volume, or by venoconstriction reducing venous compliance — and venous return rises.
  • Raise right atrial pressure and venous return falls, because the gradient narrows.
  • Raise the resistance to venous return — posture, or vascular compression from pregnancy, obesity or a laparoscopic pneumoperitoneum — and venous return falls.

Where the circulation settles

Plot venous return against right atrial pressure and the line falls as right atrial pressure rises. Plot the cardiac function curve on the same axes and it rises with right atrial pressure, because right atrial pressure is the right ventricle’s preload. The circulation settles at the one point satisfying both: where the two curves cross.

  • A negative inotrope flattens the cardiac function curve, so the crossing point moves to a lower output at a higher right atrial pressure.
  • Haemorrhage lowers MSFP, shifting the venous return line left, so output falls.
  • Volume loading raises MSFP, shifting the line right, so output rises — provided the heart is still on the steep part of its own curve.
Venous return line falling to zero at a mean systemic filling pressure of about 7 mmHg, crossing the cardiac function curve at 5 L/min; haemorrhage and a negative inotrope move the crossing to a lower output
Figure 3 — Cardiac output settles where the venous return and cardiac function curves cross. Haemorrhage or a negative inotrope moves that point to a lower output.

Under positive pressure ventilation: raising intrathoracic pressure raises right atrial pressure, narrows the gradient for venous return and cuts preload. This is why cardiac output can fall sharply when a hypovolaemic patient is intubated and ventilated, and why high tidal volumes or high positive end-expiratory pressure (PEEP) make it worse in an underfilled patient.

Why CVP misleads: CVP is a pressure being read as a stand-in for volume, at a point where the relationship between the two depends on venous tone, ventricular compliance and intrathoracic pressure. A single CVP reading says little about whether a patient will respond to fluid. What it does say is where right atrial pressure sits in the equation above — a high CVP is itself a brake on venous return.

In tamponade and constrictive pericarditis: the pericardium limits how far the ventricle can fill, so right atrial pressure climbs while end-diastolic volume stays low. Preload is low despite a high filling pressure, which is the clearest demonstration that pressure and volume are not interchangeable.

What heart failure does to the curve

A heart with reserve sits on the steep part of a normal curve. Heart failure is the point at which the heart can no longer produce enough cardiac output to meet the demands of the tissues, and each of its forms is a specific change to that curve.

Clinically it is a syndrome: breathlessness, ankle swelling and fatigue, with or without a raised jugular venous pressure (JVP), crackles at the lung bases and peripheral oedema, caused by a structural or functional abnormality of the heart that reduces cardiac output or raises intracardiac pressures.

The first split is by output:

  • Low-output failure — tissue oxygen demand is normal, but cardiac output can’t meet it. This is what is usually meant by heart failure.
  • High-output failure — cardiac output is normal or high, but demand is higher still. Thyrotoxicosis and pregnancy are the standard examples.

The second split is by what has gone wrong mechanically, and the two behave very differently.

Systolic failure: the curve drops

The pump is weak, so a smaller fraction of the end-diastolic volume is ejected each beat.

EF (%) = (EDV − ESV) / EDV × 100

where:
EF (%) = ejection fraction
EDV (mL) = end-diastolic volume
ESV (mL) = end-systolic volume

Current terminology names this by the number: heart failure with reduced ejection fraction (HFrEF), a left ventricular ejection fraction (LVEF) below 40%. An LVEF of 40–49% is heart failure with mid-range ejection fraction (HFmrEF).

It arises in two ways:

  • Myocyte dysfunction — ischaemia from coronary artery disease, infarction with scar formation, myocarditis, or a congenital or acquired cardiomyopathy. Stroke volume falls, end-diastolic volume rises, and the heart dilates.
  • Chronically raised afterload — systemic hypertension or aortic stenosis. The ventricle hypertrophies to compensate, and once further rises in afterload outstrip what hypertrophy can absorb, stroke volume falls and end-diastolic volume rises.

On the curve the whole line sits lower and flatter: at any given preload the stroke volume is smaller, and the maximum achievable stroke volume is lower. Drawn as a pressure–volume loop, the end-systolic pressure–volume relationship becomes less steep and end-systolic volume rises.

Diastolic failure: the ventricle will not fill

Here contractility is normal and the problem is filling. A stiff, poorly compliant ventricle needs a higher pressure to accept the same volume, so end-diastolic volume is reduced, and stroke volume falls with it even though the pump works. The ejection fraction is preserved, because a normal fraction of a smaller volume is being ejected: this is heart failure with preserved ejection fraction (HFpEF), an LVEF of 50% or more.

Causes are impaired relaxation (ischaemic heart disease, restrictive cardiomyopathy) or pathological hypertrophy (hypertension, hypertrophic obstructive cardiomyopathy, aortic stenosis).

Pressure–volume loops: in systolic failure the ESPVR is flatter and the loop shifts right with a smaller stroke volume; in diastolic failure the EDPVR is steeper and the loop is narrower at higher filling pressure
Figure 4 — Systolic failure flattens the ESPVR and shifts the loop right; diastolic failure steepens the EDPVR so a smaller volume fills at a higher pressure.

In diastolic failure: atrial contraction matters far more than usual, because it is doing the work of pushing blood into a stiff ventricle, and a fourth heart sound is often audible. The onset of atrial fibrillation can be disastrous — the atrial kick is lost and a fast rate cuts filling time, so end-diastolic volume drops twice over. Rate control with β-blockers or calcium channel antagonists protects filling, though calcium channel blockers are avoided where the ejection fraction is reduced.

Decompensation turns the curve downward

In advanced failure the ventricle dilates so far that the sarcomeres are stretched past their optimum length. The length–tension relationship then runs backwards: more filling means fewer cross-bridges and less force, so the curve stops flattening and begins to descend. Past that point, giving volume reduces stroke volume.

A dilated ventricle is at a mechanical disadvantage as well. By LaPlace’s law, wall tension rises with chamber radius, so a larger ventricle must generate more wall tension to produce the same pressure — more work done, and more oxygen consumed, for the same output.

Acutely, the pericardium limits how far the ventricle can dilate, which puts a brake on this process in the short term.

How the failing heart compensates

A ventricle whose curve has dropped can still deliver a normal cardiac output for a long time, because the body recruits two mechanisms that lift it back up. That state is compensated heart failure: ventricular function is impaired, output is maintained.

  • Sympathetic activation. Raised contractility lifts the curve, and a faster heart rate keeps cardiac output up despite a smaller stroke volume.
  • Expansion of blood volume. A fall in cardiac output reduces renal blood flow, and the kidney responds through the renin–angiotensin–aldosterone system by retaining salt and water. Preload rises and the ventricle moves further along its curve. Atrial and brain natriuretic peptides, released by the stretched heart, oppose this with a natriuresis — which is also why brain natriuretic peptide is raised and is used in diagnosis.

Why compensation runs out

  • Sustained sympathetic drive downregulates cardiac β-receptors, so the heart becomes steadily less responsive to catecholamines — its own, and the ones we give.
  • Salt and water retention keeps pushing preload upwards, and once the ventricle is past its optimum sarcomere length the extra volume reduces stroke volume instead of increasing it.
  • Whatever the cause, the heart is doing more work for the same output, so myocardial oxygen demand is higher and cardiac reserve is lower.

When compensation fails, output falls and the patient decompensates. Two vicious cycles drive it:

  • Low output → reduced coronary blood flow → myocardial ischaemia → worse contractility → lower output still. Taken far enough, this is cardiogenic shock.
  • Pulmonary oedema → increased work of breathing → more negative intrathoracic pressure → higher left ventricular afterload → worse left ventricular failure → more pulmonary oedema.

Backward failure

The rise in end-diastolic volume raises the pressure in the atrium behind it, and that pressure is transmitted back into the capillary beds upstream, where it tips the Starling filtration forces towards fluid leaving the circulation.

  • Raised left atrial pressure → raised pulmonary capillary pressure → fluid moves into the lung interstitium → pulmonary oedema and breathlessness. Lying flat shifts blood from the legs into the thorax, which the failing left ventricle can’t clear, producing orthopnoea and paroxysmal nocturnal dyspnoea.
  • Chronically raised pulmonary venous pressure raises right ventricular afterload and can bring on right ventricular failure in turn.
  • Raised right atrial pressure → raised central venous pressure → oedema in dependent areas first (ankles, sacrum), then ascites and hepatomegaly with liver dysfunction.

The failing ventricle in theatre

The anaesthetic problem follows from the curve: the ventricle has little reserve, it tolerates underfilling and overfilling equally badly, and most of our drugs push it the wrong way. Heart failure is an independent predictor of perioperative major adverse cardiac events and mortality, and unstable or decompensated failure carries the greatest risk.

Preoperatively: look for recent decompensation. Orthopnoea and paroxysmal nocturnal dyspnoea are the most sensitive symptoms, and a raised JVP the most sensitive sign. Exercise tolerance graded on the New York Heart Association (NYHA) classification gives a measure of reserve, and echoc is the main investigation, giving the ejection fraction and an estimate of filling pressures. Continue heart failure medication, including β-blockers, through the perioperative period.

Fluid management: the failing ventricle is already on the flat part of its curve, so a bolus raises filling pressure far more than it raises output, and the surplus ends up in the lungs. Give fluid in small measured aliquots against a defined endpoint, and judge the response on flow rather than on pressure.

Rate and rhythm: protect filling time and the atrial kick. Treat new arrhythmias early, correct electrolytes, and consider direct current cardioversion if the patient is haemodynamically unstable. For chronic arrhythmias a rate of around 80 beats/min is a reasonable target.

Ventilation: positive pressure ventilation cuts venous return, which the underfilled failing heart tolerates badly, but it also reduces left ventricular afterload, which the overloaded left ventricle tolerates well. The net effect depends on which problem dominates. Where the right ventricle is the weak side, avoid hypoxia, hypercapnia and acidosis, because all three raise pulmonary vascular resistance and so raise right ventricular afterload.

Monitoring and support: invasive arterial pressure, central venous access and, for major surgery, a cardiac output monitor or transoesophageal echocardiography. Decompensation may need an inotrope — dobutamine or milrinone, which combine inotropy with vasodilatation — and a vasopressor alongside it if systemic pressure falls. Plan postoperative care in a high dependency or intensive care setting.

Analgesia: good postoperative analgesia is important physiologically as well as humanely, because pain drives catecholamine release, and that raises heart rate and afterload in a ventricle that tolerates neither.

In short

  • Stretching cardiac muscle before it contracts makes the next contraction stronger, because filament overlap and calcium sensitivity both improve. That is the Frank–Starling mechanism, and it is intrinsic to the muscle.
  • Maximum force comes at a sarcomere length of about 2.2 µm, corresponding to an LVEDP of roughly 10–12 mmHg. Stretch beyond that and force falls.
  • Plotted as preload against stroke volume, the relationship is steep at normal filling and flat at high filling. Changing preload moves the heart along its curve; changing contractility moves it onto a different curve.
  • The mechanism matches right and left ventricular output automatically, beat by beat.
  • Cardiac output settles where the cardiac function curve crosses the venous return curve, so the heart and the circulation set it together.
  • In systolic failure the curve sits lower and flatter and the ejection fraction falls below 40%. In diastolic failure the ventricle is stiff, filling is reduced, and the ejection fraction is preserved at 50% or more.
  • Sympathetic drive and salt and water retention compensate until β-receptors downregulate and the ventricle passes its optimum sarcomere length. After that, extra filling lowers output and pressure backs up behind the ventricle.
  • In theatre that means little reserve, poor tolerance of both underfilling and overfilling, a negatively inotropic induction, and a reliance on rate, rhythm and measured fluid rather than volume loading.

Related Posts

LaPlace’s law

Every hollow structure in the body holds a pressure. The left ventricle squeezes blood at well over 100 mmHg, arteries

Read More