MAC – minimum alveolar concentration

In this note:

MAC (or technically MAC50) is a key concept in volatile anaesthesia.

It is defined as:

‘The alveolar concentration of an inhaled anaesthetic agent that prevents movement in 50% of patients in response to a standard surgical stimulus (e.g., skin incision).’

  • MAC is population-based, not patient-specific — some individuals will require more, others less.

  • Inverse to potency: low-potency agents need a higher alveolar concentration to prevent movement; high-potency volatiles achieve this with a lower MAC.

  • This aligns with the Meyer–Overton hypothesis: anaesthetic potency increases with lipid solubility (oil : gas partition coefficient).

  • Therefore there is an inverse relationship between MAC and the oil : gas coefficient.

  • Additive: when two inhaled agents are used together (e.g. N₂O + sevoflurane), their MAC values add.

Two things to bear in mind:

  • MAC values are always in the absence of any other drugs, whereas in practice patients will often have something else on board.

  • Since MAC just stands for mean alveolar concentration, we have to be careful what we are referencing: MAC50 is the typical definition (50% of the population won’t respond), but there are different MAC targets depending on the anaesthetic effect you’re aiming for.

Different MAC Targets

These are less clinically useful than our traditional MAC but useful to be aware of: 

MAC₉₀ and MAC₉₅: 

  • MAC₉₀ and MAC₉₅ describe the upper end of the dose–response curve for immobility.

  • Because the standard deviation of MAC is ~0.1, ~95% of patients won’t move with 1.2 MAC.

  • This can act as a target for surgical anaesthesia if we were to not use opioids or NMBs. 

MAC Intubation

  • Intubation requires deeper anaesthesia than skin incision.

  • 1.3 MAC prevents somatic and autonomic responses to laryngeal stimulation (e.g., coughing, bucking).

  • Again, in practice, we will supplement with some combination of opioids, muscle relaxants, or local anaesthetic  so this is a theoretical target. 

MAC Awake

  • The MAC at which 50% of patients open their eyes to voice during emergence.

  • Useful for judging the transition out of anaesthesia.

  • Typically 0.3–0.4 MAC, but for nitrous oxide it’s much higher (~0.65 MAC) — explains its limited amnesic properties.

MAC-BAR (Block Adrenergic Response)

  • This is the concentration needed to block increases in BP and HR in response to noxious stimuli like incision.

  • Higher than MAC for immobility because adrenergic responses persist even without movement.

  • Typically ~1.5 MAC.

  • Again opioids will reduce the MAC needed to achieve this.

MAC.hr (MAC-Hours)

  • A way to quantify exposure over time:

    • 1 MAC.hr = 1 hour at 1 MAC, or 2 hours at 0.5 MAC, etc.

  • Used in comparative studies and modelling context-sensitive decrement times.

What is a MAC of 1 on the Anaesthetic Machine?

  • Each volatile agent has a published MAC value in % (MAC50): the alveolar % at which 50% of a population won’t move to a standard surgical stimulus (e.g. sevoflurane ~1.8%).

  • Because the published MAC for sevo (e.g. 1.8%) comes from population studies, it represents the middle of a bell-shaped spread: some patients will need more than 1.8% to prevent movement, and some will need less.

  • It would be silly to give 1.8% of sevo to septic 95 year-old Doris (apologies to any Doris’ reading) as well as to a very anxious 120kg 18 year old and expect it to have the same effect. 

  • The actual alveolar concentration needed for an individual varies, mainly with age (biggest effect) and weight, plus other factors (temperature, physiology, etc.).

  • Because we can’t personalise MAC for every variable, the machine uses what we can enter (especially age, and weight) and applies population study data to estimate an age-adjusted MAC% for a “typical” patient like yours.

  • So “1 MAC” on the machine is a ratio:

    • MAC multiple = measured end-tidal % ÷ estimated (age-adjusted) MAC%

    • 1.0 MAC means you’re at the patient’s individualised estimated MAC50; obviously 0.7 MAC is below and 1.2 MAC is above.

Factors Affecting MAC

As we now know, different patients need different alveolar concentrations of volatile agent to keep them asleep.

 

  • ↓ MAC = you need less volatile to prevent movement → patient is more sensitive.

  • ↑ MAC = you need more volatile → patient is less sensitive.

 

Factors that decrease MAC (↑ sensitivity)

Age

  • Neonates and the elderly

CNS depressants (reduce the volatile needed because they add sedation)

  • Opioids, benzodiazepines, α₂ agonists

Physiological states

Anything that reduces overall CNS arousal / neuronal activity or reduces the body’s capacity to mount a response tends to mean you need less volatile

  • Pregnancy

  • Hypothermia

  • Hyponatraemia

  • Acidosis

  • Hypotension

  • Hypoxia

Drugs (again addition of other sedatives lower MAC requirement)

  • Acute alcohol intoxication

  • Lithium

  • Ketamine

 

Factors that increase MAC (↓ sensitivity)

Age

  • Infants and children

CNS stimulation (increases arousal/activation, so more volatile needed)

  • Anxiety

Drugs

  • Chronic alcohol use (sensitisation to CNS depressants)

  • MAOIs, cocaine, amphetamines

Physiological states

  • Hyperthermia

  • Hypernatraemia

 

Factors with no effect on MAC
  • Duration of anaesthesia

  • Gender

  • Hypertension

  • Anaemia

  • Magnesium and potassium levels