Pathological Ventricular Pressure-Volume Loops

In this note:

Once you understand the normal pressure–volume (P–V) loop, the next step is to understand how and why its shape changes when physiology changes.

This often comes up in the Primary FRCA, exam questions can test whether you can look at a loop and infer:

  • what has changed
  • why the loop looks different
  • what this means for stroke volume, pressure generation etc 

Or, they might give you a clinical scenario, and ask you to draw/modify a pressure volume loop to fit. Either way, avoid memorising the shapes in isolation. It’s always better to be able to build them up from first principles. 

Recap

Complete left ventricular pressure–volume loop showing the four phases of the cardiac cycle. The x-axis shows LV volume in mL from 0 to 250, and the y-axis shows LV blood pressure in mmHg from 0 to 160. The loop begins at about 50 mL and very low pressure where the mitral valve opens, then moves rightward along a shallow filling curve to about 125 mL where the mitral valve closes. A vertical line then rises at constant volume to about 80 mmHg where the aortic valve opens, representing isovolumetric contraction. The ejection phase curves up and left to a peak just above 120 mmHg before ending at about 50 mL and 120 mmHg where the aortic valve closes. A final vertical line descends at constant volume back to the starting point, representing isovolumetric relaxation. A dashed red line labelled ESPVR passes through the end-systolic point. Dotted guide lines mark end-systolic volume, end-diastolic volume, diastolic blood pressure, and systolic blood pressure. A horizontal double-headed arrow between the two vertical sides is labelled stroke volume.

A left ventricular P–V loop plots:

  • LV volume on the x-axis
  • LV pressure on the y-axis

over one cardiac cycle.

The loop moves anticlockwise through four phases:

Diastolic filling
  • mitral valve open
  • volume rises
  • pressure changes little
Isovolumetric contraction
  • mitral valve closed
  • aortic valve not yet open
  • pressure rises at constant volume
Ventricular ejection
  • aortic valve open
  • volume falls
  • pressure rises then falls
Isovolumetric relaxation
  • aortic valve closed
  • mitral valve not yet open
  • pressure falls at constant volume

Key measurements:

  • SV = EDV − ESV
  • Width of the loop = stroke volume
  • Area inside the loop = external stroke work

What changes with increased preload?

Preload is the degree of myocardial fibre stretch at the end of diastole. Essentially how full the ventricle is after filling. 

In practical terms, on the P–V loop it is most closely reflected by:

  • end-diastolic volume
  • and to some extent end-diastolic pressure

So when preload increases, the ventricle starts contraction when it is more filled.

What increases preload? 

Typical causes include:

  • increased venous return
  • fluid administration
  • venoconstriction
  • slow heart rate allowing more filling

What happens to the loop?

The loop shifts to the right and becomes wider. ESV may remain similar or rise slightly, but the dominant effect is the increase in EDV and SV.

Because:

  • the ventricle fills to a larger EDV
  • greater sarcomere stretch leads to a stronger contraction
  • more blood is ejected

This is the Frank–Starling mechanism.

Effect on stroke work and oxygen demand

Because the loop is larger, the area inside the loop increases, so:

  • external work increases
  • myocardial oxygen demand also increases

This makes sense: ejecting a larger volume means the heart is doing more useful work.

Drawing the loop with increased preload

When drawing any LV pressure–volume loop, remember two rules:

  • The filling (bottom) line must always lie along the EDPVR, because ventricular filling occurs according to the ventricle’s passive diastolic compliance. The ventricle cannot choose an arbitrary filling path — at any given diastolic volume, its pressure is determined by the End-Diastolic Pressure–Volume Relationship.

 

  • The loop cannot cross beyond the ESPVR, because the ESPVR represents the maximum pressure the ventricle can generate at any given volume at end systole. It is the ventricle’s contractile limit. A normal beat can end on the ESPVR or below it, but it cannot pass beyond it.

With that in mind, draw the loop as follows.

 

1. Start with the normal loop

First draw a normal LV pressure–volume loop with its four phases:

  • diastolic filling along the EDPVR
  • vertical isovolumetric contraction
  • ejection up and left toward the ESPVR
  • vertical isovolumetric relaxation

This gives you a reference loop to compare with.

 

2. Increase the end-diastolic volume

In increased preload, more blood returns to the ventricle during diastole, so the ventricle fills to a larger EDV.

To show this:

  • move the bottom right corner of the loop further to the right
  • make sure this new point still lies on the EDPVR

 

3. Draw the filling limb along the EDPVR

Now redraw the filling phase from the old end-systolic volume to the new higher EDV.

Important point:

  • this line must follow the EDPVR

Why? Because as the ventricle fills, pressure rises according to its passive elastic properties. At low volumes, the pressure rise is small, but at higher volumes the pressure starts to rise more steeply.

 

4. Draw isovolumetric contraction vertically upward from the new EDV

Once filling ends and the mitral valve closes, the ventricle begins contracting with no change in volume.

So:

  • draw a vertical line upwards from the new, right-shifted EDV point

 

5. Draw the ejection limb up and left — but never beyond the ESPVR

Because preload is increased, myocardial fibres are stretched more at end diastole. Via the Frank–Starling mechanism, this produces a stronger contraction and a larger stroke volume.

So:

  • draw the ejection limb curving upwards and leftwards
  • This should be above (at higher pressures) than the reference curve
  • but make sure the end-systolic point does not pass beyond the ESPVR

Why? The ventricle can eject more because increased preload improves force generation, but the beat is still constrained by the ventricle’s maximal systolic capability. The ESPVR is the upper contractile boundary: the ventricle cannot generate an end-systolic pressure–volume point beyond that line.

In pure increased preload, contractility has not changed, so the ESPVR itself does not move.

 

6. Draw isovolumetric relaxation vertically downward

From the end-systolic point, draw a vertical line downwards.

This should be at a slightly higher end-systolic volume than the reference curve as we’ve hit the ESPVR line earlier. 

 

7. Compare it with the original loop

The finished loop should now show:

  • a rightward shift of the right border because EDV has increased
  • a wider loop because stroke volume has increased
  • the filling limb still lying on the EDPVR
  • the end-systolic point still constrained by the ESPVR

 

8. Physiological summary of why it looks this way

The altered shape reflects the physiology:

  1. increased venous return increases EDV
  2. the ventricle therefore moves further along the EDPVR during filling
  3. greater fibre stretch increases force of contraction by Frank–Starling
  4. the ventricle ejects more blood
  5. the loop becomes wider
  6. but the beat still cannot go beyond the ESPVR, because that line defines the ventricle’s maximal end-systolic performance for that contractile state

Why should I care?

If we were to:

  • Give intravenous fluids/blood products
  • Perform a straight leg raise to guage fluid responsiveness 

A normal ventricle may respond with an increased stroke volume.

However, in a failing heart or a stiff ventricle, as we’ll see later, increasing preload may produce:

  • only a small rise in SV
  • but a large rise in filling pressure

So more preload is only helpful if the ventricle is still operating on the responsive part of the Frank–Starling curve.

Increased afterload

Afterload is the force opposing ventricular ejection.

In simple clinical terms, it is often approximated by:

  • aortic pressure
  • systemic vascular resistance

More precisely, it is the load the ventricle must overcome to eject blood.

 

What increases afterload? 

  • vasopressors
  • hypertension
  • aortic stenosis

What happens to the loop?

The loop becomes taller and narrower.

This is because the ventricle must generate more pressure before the aortic valve can open, and once ejection begins, it empties less effectively.

Left ventricular pressure–volume loop showing the effect of increased afterload. The darker blue loop is taller and narrower than the lighter baseline loop. End-systolic pressure is higher and end-systolic volume is increased, indicating more blood remains in the ventricle after ejection. End-diastolic volume is normal or slightly increased. Stroke volume is reduced, shown by the narrower loop width. The ESPVR and EDPVR curves are unchanged, indicating unchanged contractility and compliance. Labels highlight increased systolic and diastolic blood pressure, increased end-systolic volume, and decreased stroke volume.

Drawing the loop with increased afterload

 

1. Start from a slightly higher end-diastolic volume

Increased afterload reduces ventricular emptying, so more blood is left behind at the end of systole. If venous return continues normally, this residual volume adds to the next beat’s filling volume, so EDV becomes slightly higher.

So:

  • start from a point slightly further to the right than the normal EDV

  • make sure this point still lies on the EDPVR

2. Draw isovolumetric contraction higher before the aortic valve opens

With increased afterload, the ventricle must generate a higher pressure before LV pressure exceeds aortic pressure and the aortic valve can open.

So:

  • draw the right vertical line higher than normal before ejection begins

Why? Because as aortic pressure is higher, the ventricle must climb to a higher pressure before ejection can start.

 

3. Draw the ejection limb beginning later and at a higher pressure

Once the aortic valve opens, ejection begins — but it is now occurring against a greater opposing force.

So:

  • start the ejection limb higher up

  • curve it leftward less than normal

Why? Because ejection is more difficult when afterload is increased. The ventricle spends more of systole generating pressure and is less able to shorten effectively, so less blood is ejected. 

 

4. End ejection earlier at a larger end-systolic volume

Because the ventricle cannot empty as effectively against the increased afterload:

  • the end-systolic point shifts to the right

  • the loop ends at a larger ESV

Importantly:

  • this end-systolic point should still lie on the ESPVR

Why? Because the ESPVR is still the contractile limit for that ventricle. In pure increased afterload, contractility has not changed, so the ESPVR itself does not move. The ventricle simply reaches its systolic endpoint earlier and at a larger residual volume.

 

5. Draw isovolumetric relaxation vertically downward

After the aortic valve closes:

  • draw a vertical line downward from the new, right-shifted end-systolic point

 

6. Complete filling along the EDPVR

To complete the beat:

  • draw the filling limb back to the slightly increased EDV along the EDPVR

 

7. Compare it with the original loop

Your finished loop should now show:

  • a slightly increased EDV

  • a higher peak pressure

  • a larger ESV

  • a reduced stroke volume

  • a loop that is taller and narrower

 

Why it looks this way

The altered shape reflects the physiology:

  1. increased afterload means the ventricle must overcome a higher outflow pressure

  2. it therefore spends longer in isovolumetric contraction, building pressure before the aortic valve opens

  3. ejection begins at a higher pressure

  4. fibre shortening is more limited, so less blood is ejected

  5. ESV rises

  6. This contributes to a slightly higher EDV

  7. But overall, SV falls

  8. the loop becomes taller and narrower

This is also why increased afterload is so energetically costly: the ventricle is doing more pressure work, which increases wall tension and myocardial oxygen demand.

Why should I care

This matters in situations like:

  • laryngoscopy causing sympathetic surge
  • poorly controlled hypertension
  • vasopressor excess
  • aortic stenosis

Clinical consequences of these include:

  • reduced stroke volume
  • increased myocardial oxygen demand
  • higher risk of ischaemia, especially in coronary disease

This is why we aim to avoid sudden increases in afterload in patients with a dodgy heart. It is also a very important downside of vasopressors.

Changes in contractility

Contractility is the intrinsic ability of the myocardium to generate force independent of preload and afterload.

On the P–V loop, it is best represented by the ESPVR. Let’s start with increased contractility. 

Increased contractility

A steeper ESPVR means an increased contractility:

  • stronger contraction
  • more pressure generated at a given volume
  • more complete emptying
 

What increases contractility?

  • sympathetic stimulation
  • inotropes (adrenaline, dopamine etc) 
  • increased intracellular calcium availability

What happens to the loop with increased contractility?

The ESPVR steepens and shifts up and left.

The loop becomes wider, and the left border moves further left because ESV falls.

 

Left ventricular pressure–volume loop showing the effect of increased contractility. The darker blue loop is shifted to the left compared with the lighter baseline loop, with a steeper end-systolic pressure–volume relationship (ESPVR). End-systolic volume is decreased while end-diastolic volume is unchanged, so stroke volume is increased and the loop is wider. Peak systolic pressure is slightly higher. The end-diastolic pressure–volume relationship (EDPVR) is unchanged, indicating unchanged ventricular compliance. Labels highlight increased contractility, decreased end-systolic volume, normal end-diastolic volume, and increased stroke volume.

Why? 

If contractility increases:

  1. the ventricle contracts more forcefully
  2. it generates greater pressure for any given volume
  3. it ejects more completely
  4. ESV decreases
  5. SV increases
  6. ejection fraction increases

So compared with normal:

  • end-systolic point moves up and left
  • loop widens
  • systolic performance improves

Effect on work and oxygen demand

A stronger contraction increases:

  • stroke work (area within the loop), and therefore
  • myocardial oxygen demand

Even though output improves, it comes at an energetic cost.

Decreased contractility

What causes reduced contractility?

  • myocardial ischaemia

  • systolic heart failure

  • cardiomyopathy

  • Direct myocardial depressants:

      • volatile anaesthetic agents

      • propofol

      • severe acidosis

What happens to the loop?

The ESPVR flattens and shifts down and right. 

The loop becomes narrower, and the end-systolic point shifts rightward (increased ESV, reduced SV and ejection fraction).

Step-by-step reasoning

If contractility falls:

  1. the ventricle generates less force
  2. it cannot empty as effectively
  3. ESV rises
  4. SV falls
  5. ejection fraction falls

So the heart leaves more blood behind at the end of systole.

Initially, the body may compensate by increasing preload, which pushes EDV up in an attempt to maintain SV via Frank–Starling mechanisms.

That may help temporarily, but beyond a point the ventricle becomes overstretched and performance worsens.

What about diastolic failure?

Left ventricular diastolic failure means the ventricle has impaired filling because it is abnormally stiff, poorly compliant, or relaxes inadequately during diastole. The problem is therefore not primarily one of weak contraction, but of difficulty accepting blood at a low pressure.

This is often described clinically as heart failure with preserved ejection fraction (HFpEF), although the two terms are not always perfectly interchangeable. In exam terms, the key idea is that systolic emptying may be relatively preserved, but filling is abnormal and occurs at a higher pressure.

 

Core physiological problem

A normal ventricle fills easily at low pressure because it is compliant. In diastolic failure, the ventricle is less compliant, so even a modest increase in filling volume causes a disproportionate rise in pressure.

This means:

  • LV end-diastolic pressure rises
  • left atrial pressure must rise to maintain filling
  • pulmonary venous pressure rises
  • the patient becomes prone to pulmonary congestion and oedema

So the ventricle may contain a near-normal volume, but it can only achieve this at the cost of abnormally high filling pressures.

Possbile causes

Typical causes are conditions that make the ventricle stiff, thickened, or slow to relax, such as:

  • left ventricular hypertrophy from chronic hypertension
  • aortic stenosis
  • ischaemia
  • age-related ventricular stiffening
  • hypertrophic or restrictive cardiomyopathy

These are all states in which the ventricle becomes less able to distend during diastole.

Effect on the pressure–volume loop

The main change is in the EDPVR.

  • The EDPVR shifts up and to the left
  • it becomes steeper

Because for any given ventricular volume, the pressure is now higher than normal. The ventricle is stiffer, so it resists filling.

Left ventricular pressure–volume loop illustrating diastolic dysfunction from reduced ventricular compliance. The darker blue loop is narrower and shifted left compared with the lighter baseline loop. The end-diastolic pressure–volume relationship is shifted upward and leftward, showing a stiffer ventricle with higher filling pressure at any given volume. End-diastolic volume is reduced because the ventricle fills less, while end-systolic volume is unchanged. Stroke volume is therefore decreased. A normal ESPVR is shown, indicating preserved systolic contractility, while labels highlight decreased stroke volume, lower EDV, unchanged ESV, and a low-compliance ventricle.

How to draw the loop

  1. Start with the normal loop for reference
  2. Draw a steeper, upward-shifted EDPVR
  3. Keep the ESPVR roughly the same if systolic contractility is preserved
  4. Start filling from the same or slightly reduced ESV
  5. Draw the filling limb along the new steeper EDPVR
  6. Stop at a lower EDV, this will be at a higher end-diastolic pressure
  7. Draw isovolumetric contraction upward as usual
  8. Draw ejection toward the same ESPVR
  9. Complete isovolumetric relaxation vertically downward

Right ventricular pressure-volume loop

Although the right and left ventricles must eject the same stroke volume to maintain matched cardiac outputs, the right ventricular (RV) pressure–volume loop looks quite different from the left ventricular loop because the RV pumps into the low-resistance, high-compliance pulmonary circulation.

 

Main differences from the LV loop

The LV loop is usually drawn as a more rectangular shape because the left ventricle generates high pressures and has well-defined isovolumetric contraction and isovolumetric relaxation phases.

The RV loop, by contrast, is more triangular. This is because the pulmonary valve opens at a much lower pressure, so ejection begins early in systole, before a prominent vertical isovolumetric contraction phase can develop. Similarly, relaxation is less sharply separated from ejection, so the isovolumetric relaxation phase is also less distinct.

Pressure–volume loops comparing the left and right ventricles. The larger pale loop represents the left ventricle, reaching much higher pressures, while the smaller dark blue loop represents the right ventricle, operating at much lower pressures but over a similar volume range. The right ventricular loop is more triangular in shape, with phases labelled RV filling, RV contraction, and RV relaxation. Both loops are plotted against ventricular volume on the x-axis and blood pressure on the y-axis.

Pressure and afterload

The RV operates at much lower pressures than the LV.

Typical values are approximately:

  • RV: 25 / 0 – 5 mmHg
  • LV: 120 / 10 mmHg

This reflects the much lower afterload faced by the RV, as pulmonary vascular resistance is only about one-tenth of systemic vascular resistance.

Because of this low afterload:

  • the RV does not need to generate high pressure before ejection starts
  • volume begins to fall early in systole
  • ejection continues even while RV pressure is already falling

In fact, a substantial proportion of RV stroke volume is ejected after peak systolic pressure has been reached, which is very different from the LV.

 

Work and energetics

Although both ventricles eject the same stroke volume, the area inside the RV loop is much smaller because the RV ejects blood at a far lower pressure. So

RV stroke work is only about 20 – 25% of LV stroke work

This makes sense from first principles: if work depends on pressure × volume change, then ejecting the same volume at a much lower pressure requires much less work.

 

Clinical and anaesthetic relevance

The RV is normally efficient in a low-pressure system, but this also makes it highly sensitive to acute increases in afterload.

So the RV may fail rapidly in situations such as:

  • pulmonary hypertension
  • pulmonary embolism
  • hypoxia
  • hypercapnia
  • high intrathoracic pressure or excessive positive-pressure ventilation

This is a key anaesthetic point: the RV generally tolerates volume loading better than sudden increases in pulmonary vascular resistance.

 

In short

  • The RV pressure–volume loop is triangular, unlike the more rectangular LV loop.
  • The RV has poorly defined isovolumetric phases because ejection begins early at low pressure.
  • The RV operates at much lower pressures because it pumps into the low-resistance pulmonary circulation.
  • The area inside the RV loop, and therefore stroke work, is much smaller than in the LV.
  • The RV is very sensitive to increases in afterload, which is why acute pulmonary hypertension can cause rapid RV failure.

Related Posts

LaPlace’s law

Every hollow structure in the body holds a pressure. The left ventricle squeezes blood at well over 100 mmHg, arteries