For a reminder of the anatomy of coronary vasculature, have a read through teachmeanatomy’s post here.
Coronary blood flow is mostly a pressure gradient problem
Blood flows through any vascular bed when there is a pressure gradient:
Flow ∝ ( P upstream − P downstream ) / Resistance
So the first question is always: what counts as “upstream” and “downstream” pressure for that bed?
For the coronaries:
Upstream pressure is roughly the pressure at the coronary ostia in the aortic root (where the arteries originate). In practice, this pressure roughly equals aortic root pressure.
Downstream pressure or ‘back pressure’ is more complicated than just the venous pressure because much of the coronary microcirculation lies within contracting myocardium. Small intramyocardial vessels behave like collapsible tubes: if the pressure outside the vessel rises, the vessel narrows, resistance increases, and flow falls. In the LV, that outside pressure rises dramatically in systole because wall tension is high.
So at any moment, coronary flow is set by the balance of:
Driving pressure: aortic root pressure pushing blood into the coronaries.
Opposing pressure:
Intramyocardial compressive pressure that squeezes the intramyocardial vessels, plus
The pressure inside the ventricle at end-diastole (LVEDP), which acts as a back-pressure to coronary perfusion.
Because both the driving pressure and the opposing pressures vary across the cardiac cycle, coronary blood flow varies across the cardiac cycle too.
The driving pressure changes because aortic root pressure is different in systole and diastole.
The opposing pressures change because:
LV contraction in systole increases intramyocardial (extravascular) compressive pressure on the coronary microvessels
The downstream “back-pressure” component related to LV filling pressure (LVEDP) also influences the effective gradient.
So, as the balance between driving pressure and opposing pressures shifts from systole to diastole, the pressure gradient available to push blood through the coronaries changes—meaning coronary flow depends on which phase of the cardiac cycle you’re in.
That’s why coronary flow is called ‘phase-dependent’, particularly in the LV:
Systole increases compressive pressure → raises effective downstream pressure and resistance → limits flow.
Diastole removes compression → restores vessel calibre and gradient → flow peaks, especially early diastole.
Left ventricle: why systole restricts flow
The LV generates very high wall tension during systole. That creates intramuscular pressures that can exceed coronary arterial pressure, compressing the coronaries around the LV from the outside.
What you see across the cardiac cycle:
Early systole (isovolumetric contraction): sudden rise in LV wall tension compresses intramyocardial vessels; there may be brief retrograde coronary flow.
Ejection phase: flow remains markedly reduced because the muscle is still tense.
Diastole: relaxation removes the compressive force, vessels re-open, and flow returns (maximal early in diastole).
Therefore:
The LV myocardium is predominantly perfused in diastole.
Coronary perfusion pressure
Coronary perfusion pressure (CPP) is the pressure gradient driving blood through the coronary circulation. Like any pressure gradient, it is:
ΔP = pressure in − pressure out
or
Perfusion pressure = inflow (arterial) pressure − outflow (venous/back) pressure
So, a useful formula for CPP in the LV is:
CPP = aortic diastolic pressure − LVEDP
Interpretation:
Aortic diastolic pressure is the “push”.
LVEDP is a “back-pressure” that reduces the effective gradient.
From this equation, we know that:
Anything that reduces diastolic pressure (e.g., vasodilation, low SVR, severe hypotension) reduces CPP.
Anything increasing LVEDP (e.g., LV failure, fluid overload in a stiff ventricle, high PEEP reducing venous return and affecting filling dynamics, mitral disease) will also reduce CPP.
What about in LV systole?
In LV systole, the key opposing pressure to coronary flow is no longer LVEDP. The myocardium contracts and generates very high intramyocardial (extravascular) pressure.
So the effective downstream pressure becomes much higher. We can reorganise the equation to produce:
CPP in LV systole ≈ aortic pressure − (intramyocardial pressure or LV pressure)
Why that limits flow
During systole:
Intramyocardial pressure rises sharply and can match or exceed coronary arterial pressure in the LV wall.
When the pressure outside the intramyocardial vessels ≥ the pressure inside them, those vessels collapse/compress.
That means the pressure gradient driving flow through those compressed segments falls toward zero (or briefly reverses), so flow is markedly reduced or can transiently reverse.
Right ventricle: why flow is more continuous
The RV generates much lower systolic pressures than the LV. Because intramyocardial compressive pressure is lower, RV coronary vessels are not fully compressed during systole.
So:
RV perfusion occurs in both systole and diastole (more continuous).
The perfusion gradient remains positive even in systole because aortic root pressure is still far higher than RV systolic pressure.
Practical nuance:
The RV becomes vulnerable when its systolic pressure rises markedly (e.g., acute pulmonary hypertension, massive PE). As RV systolic pressure climbs, systolic perfusion can fall because the gradient shrinks and wall stress increases.
Time in diastole is just as important
Even if CPP is fine, you still need time for flow.
Heart rate matters because:
As HR rises, time spent in diastole shortens much more than time spent in systole.
LV coronary perfusion happens almost exclusively in diastole and therefore the LV loses most of its perfusion time during tachycardia.
This is why tachycardia is so dangerous for myocardial perfusion: it reduces supply time (shorter diastole) and increases demand (more work, more oxygen consumption).
This is where regulation of coronary blood flow comes in. We’ve written a little about that here.
In summary
Chamber | Timing of Perfusion | Reason |
LV | Diastole | Systolic contraction compresses intramyocardial arterioles |
RV | Whole cycle | Lower RV pressure permits continuous flow |