After a cardiac cell fires an action potential, it can’t immediately fire again.
That “can’t fire again” time is the refractory period. It exists because the ion channels that create the action potential need time to reset into a state where they can open again.
Why this is important:
prevents the heart from being driven into tetany
helps keep conduction one-way and coordinated
limits how fast the heart can be stimulated → protects the ventricles during rapid atrial rhythms
Two key periods: ARP and RRP
1) Absolute refractory period (ARP) = no chance
During the ARP, no stimulus, no matter how strong, can trigger another action potential.
Mechanism (ventricular myocyte focus):
The fast voltage-gated Na⁺ channels that generate Phase 0 are in an inactivated state.
Inactivated channels cannot reopen until the membrane repolarises enough.
So in the ARP the cell is electrically “locked out”.
2) Relative refractory period (RRP) = possible, but difficult
During the RRP, a new action potential can be triggered, but only with a stronger-than-normal (supramaximal) stimulus.
Why?
Some Na⁺ channels have recovered, but many are still inactivated.
The membrane is still repolarising, so threshold is effectively higher and the response is often abnormal.
Clinical consequence:
A premature stimulus here can produce an abnormal beat and may precipitate arrhythmia in the wrong context.
Ventricular myocytes: why the refractory period is so long
Ventricular myocyte refractory period is ~200–250 ms, much longer than nerve tissue.
The key reason is the Phase 2 plateau:
The plateau holds the membrane at a depolarised level for a long time.
While the cell remains depolarised, Na⁺ channels stay inactivated, so the ARP stays long.
The plateau is the reason the ventricle can’t be repeatedly re-excited quickly → no tetany + time for effective systole and diastolic filling.
Where ARP and RRP sit on the ventricular action potential

Link it to phases:
ARP: begins with Na⁺ channel opening in Phase 0, continues through Phases 1 and 2, and into early Phase 3 until repolarisation is about one-third to half complete.
RRP: occurs in the later part of Phase 3, when repolarisation is nearing completion.
Remember:
ARP = “Na⁺ channels inactivated”
RRP = “Na⁺ channels recovering”
Pacemaker tissue (SA/AV node)
Nodal cells are “slow response” cells:
Upstroke depends mainly on Ca²⁺ channels (not fast Na⁺).
So refractoriness relates more to Ca²⁺ channel recovery and membrane potential behaviour.
AV node
The AV node has a prolonged refractory period which:
limits how many atrial impulses can reach the ventricles
typically prevents ventricular rates from tracking extremely fast atrial rates (e.g., in AF)
Parasympathetic stimulation
increases K⁺ permeability
hyperpolarises nodal cells
prolongs refractory period and slows AV nodal conduction
Sympathetic stimulation
increases Ca²⁺ permeability
facilitates faster recovery and conduction
shortens refractory period and speeds AV nodal conduction
Essentially vagal tone protects against fast ventricular response; sympathetic drive tends to do the opposite.
Effect of drugs on refractoriness
Class III antiarrhythmics (e.g., amiodarone, sotalol)
block outward K⁺ currents
slow repolarisation (Phase 3)
increase refractory period
reduces likelihood of re-entry circuits sustaining tachyarrhythmias
Local anaesthetics
bind preferentially to inactivated Na⁺ channels
reduce availability of Na⁺ channels for Phase 0
functionally extend refractoriness / suppress propagation, especially in fast or diseased tissue
this is why large systemic doses (or toxicity) can cause conduction slowing, QRS widening, and malignant arrhythmias, particularly with bupivacaine.