The cardiac cycle is the repeating sequence of events from one heartbeat to the next in which the ventricles fill at low pressure (diastole) and then eject at higher pressure (systole), with valves opening and closing because of pressure gradients.
The two big phases:
Diastole = ventricular relaxation + filling
- get the ventricles full at low pressure.
Systole = ventricular contraction + ejection
- generate enough pressure to open semilunar valves and eject blood.
Fundamentals
The Wiggers Diagram
The cardiac cycle is normally visualised using a Wiggers Diagram, which is a pressure/time graph including:
- Pressure – variations in left atrium, left ventricle, and aortic pressures
- Electrical events (ECG)
- Heart sounds
The cycle begins at late diastole which is a strange place to start but all graphs are drawn similarly so we should also begin there. Imagine you have just had ventricular contraction and ejection of blood from the ventricle. We enter diastolic phase and the ventricle relaxes, atrial blood floods quickly, then more slowly into the relaxing, expanding ventricle. This is chronologically where the six stages of our cardiac cycle begin.
Step-by-step through one cycle

Diastole
1) Slow filling (diastasis)
AV valves open (mitral/tricuspid)
Blood drifts from atria → ventricles because atrial pressure > ventricular pressure
This is quiet, low-pressure filling.
2) Atrial systole (“atrial kick”)
Triggered by P wave → atria contract.
Adds ~10–20% to ventricular filling at rest (can become much more important with tachycardia/exercise).
Corresponds to the a-wave on atrial/JVP waveform.
Anaesthetic relevance
Loss of atrial contraction (e.g., AF) can cause big drops in SV/CO in patients who rely on filling:
diastolic dysfunction / LVH
mitral stenosis
tachycardia (short diastole)
Systole
3) Isovolumetric contraction
Triggered by QRS → ventricles contract.
Ventricular pressure rises until it exceeds atrial pressure → AV valves close → S1.
All valves closed (AV closed, semilunar not yet open) → volume constant (isovolumetric), pressure rises sharply.
4) Ventricular ejection
When ventricular pressure exceeds aortic/pulmonary artery pressure, semilunar valves open.
Ejection is rapid early, then slower as contraction wanes and the pressure gradient decreases.
Ventricular repolarisation occurs around the T wave as systole ends and relaxation begins.
Diastole
5) Isovolumetric relaxation
Ventricles relax; when ventricular pressure falls below arterial pressure → semilunar valves close → S2.
Again all valves closed → volume constant, pressure falls quickly.
6) Rapid ventricular filling
When ventricular pressure falls below atrial pressure → AV valves open.
Blood accumulated in atria during systole empties quickly → rapid filling.
This corresponds to the y-descent on atrial/JVP waveform (atrial pressure drops as it empties).
An S3 can occur during rapid filling (physiological in young; pathological with volume overload/dilated ventricles).
Key Pressure Traces
Left Ventricular Pressure:
- Characteristic rise during isovolumetric contraction and ejection
- Peaks during systole (typically 120 mmHg)
- Falls during isovolumetric relaxation and filling
Aortic Pressure:
- Follows left ventricular pressure during ejection as the aortic valve is open
- The dicrotic notch represents aortic valve closure and elasticity/filling of arterial system
Atrial Pressure (CVP/JVP Waveform):
a-wave: Atrial systole causes a brief rise in atrial pressure
c-wave: During isovolumetric ventricular contraction, the closed AV valve bulges back into the atrium, producing a small pressure spike
x-descent: Atrial pressure falls as the atrium relaxes and the AV ring is pulled downward during early ventricular ejection, creating a suction effect that promotes atrial filling.
v-wave: Atrial pressure gradually rises as venous return fills the atrium while the AV valve remains closed through ventricular systole and isovolumetric relaxation.
y-descent: When the AV valve opens at the start of diastole, rapid emptying of the atrium into the relaxed ventricle causes a sharp drop in atrial pressure.
ECG Correlation and Timing
The ECG provides crucial timing references for mechanical events:
- P wave: Atrial depolarization, preceding atrial contraction
- QRS complex: Ventricular depolarization, preceding isovolumetric contraction and ejection
- T wave: Ventricular repolarization, occurring during ejection and preceding isovolumetric relaxation
Importantly: Electrical events always come before their corresponding mechanical events.
Heart Sounds
S1: Mitral and tricuspid valve closure at the onset of isovolumetric contraction
S2: Aortic and pulmonary valve closure at the onset of isovolumetric relaxation
S3: Pathological sound during rapid atrial filling in early diastole
- May be normal in youth or pathological in overload (e.g. HF)
S4: Pathological sound during atrial contraction in late diastole
- Almost always pathological caused by atrial contraction against stiff ventricle (LVH, fibrosis)